请选择 进入手机版 | 继续访问电脑版

机务在线

搜索
查看: 2608|回复: 3

[通用经验] ground handing power 和ground service power区别?

[复制链接]

2

主题

10

帖子

451

积分

机务学徒工

Rank: 3Rank: 3

积分
451
发表于 2024-7-13 21:07:25 | 显示全部楼层 |阅读模式 来自: 中国上海
手册看到ground handing power 和ground service power 这两个有什么区别,这两个具体描述在哪里,在SDS 24章里没找到。具体给哪些部分供电
回复

使用道具 举报

0

主题

5

帖子

0

积分

试用期机务

Rank: 1

积分
0
发表于 2024-7-15 12:53:09 | 显示全部楼层 来自: 中国山西太原
737NG只有ground service power; 744等有货舱装载系统的才区分ground handling power和ground service power.The ac GSB is powered by ac bus 1, APU generator No. 1, or external power No. 1 through the ground service select relays (GSSRs) and the ground service transfer relays (GSTRs).
The ac GSB provides 115 volt ac power to such loads as interior lights, passenger lavatory loads, and battery chargers.
The ac GHB is powered by external power No. 1 or APU generator No. 1 through the ground handling relays (GHRs). The GHB supplies power to such loads as cargo handling which are powered only on the ground.


回复 支持 1 反对 0

使用道具 举报

2

主题

10

帖子

451

积分

机务学徒工

Rank: 3Rank: 3

积分
451
 楼主| 发表于 2024-7-15 20:23:39 来自手机 | 显示全部楼层 来自: 中国上海
PHSU 发表于 2024-07-15 12:53
737NG只有ground service power; 744等有货舱装载系统的才区分ground handling power和ground service power.The ac GSB is powered by ac bus 1, APU generator No. 1, or external power No. 1 through the ground service select relays (GSSRs) and the ground service transfer relays (GSTRs).
The ac GSB provides 115 volt ac power to such loads as interior lights, passenger lavatory loads, and battery chargers.
The ac GHB is powered by external power No. 1 or APU generator No. 1 through the ground handling relays (GHRs). The GHB supplies power to such loads as cargo handling which are powered only on the ground.

哦哦,GHB只给货仓装载系统。谢谢大哥我777货机的
回复 支持 反对

使用道具 举报

1

主题

90

帖子

461

积分

机务学徒工

Rank: 3Rank: 3

积分
461
发表于 2024-11-17 23:16:24 | 显示全部楼层 来自: 中国广东深圳
望帝春心 发表于 2024-7-15 20:23
哦哦,GHB只给货仓装载系统。谢谢大哥我777货机的

不止,GHB还给加油面板的指示和控制,还有interphone系统
回复 支持 反对

使用道具 举报

您需要登录后才可以回帖 登录 | 立即注册

本版积分规则

快速回复 返回顶部 返回列表