Initial  Evaluation (1) Do this task: Wheel Well Fire, Wing and Body Overheat Detection Control Module - BITE Procedure, 26-18 TASK 801. (a) If the maintenance message does not show, this indicates an intermittent fault. 1) Do the “MEMORY CLEAR” part of this task to clear the maintenance message from the memory: Wheel Well Fire, Wing and Body Overheat Detection Control Module - BITE Procedure, 26-18 TASK 801. (b) If the maintenance message shows, do these steps


仪表评估(1)执行以下任务:轮井火灾、机翼和车身过热检测控制模块- BITE程序,26-18 TASK 801。
(a)如果维护消息未显示,则表示存在间歇性故障。1)执行此任务的“记忆清除”部分,清除内存中的维护信息:轮井火灾、机翼和车身过热检测控制模块-测试程序,26-18 TASK 801。





The front of the control module contains a MAINT ADV light, a two digit FAULT & ALARM CODE display, and four test buttons. (a) The MAINT ADV light identifies that there is fault data stored in memory. The light will stay on until corrective action is taken, and the memory is cleared. (b) The FAULT & ALARM CODE display indicates the status of the system. (c) The MEM READ switch is used to display the data stored in memory. (d) The MEM CLEAR switch is used to clear the displayed memory data. This data can only be cleared if the original fault is corrected, and there are no additional faults in the same zone. (e) The LOC TEST switch initiates the local test procedure. (f) The DISP TEST switch checks the display.


控制模块的前面包含一个主ADV灯,一个两位数的故障和报警代码显示器,以及四个测试按钮。(a)主ADV灯识别内存中存储的故障数据。指示灯将一直亮着,直到采取纠正措施,记忆被清除。(b)故障报警代码显示显示系统状态。(c)MEMREAD开关用于显示存储在内存中的数据。
(d)MEM清除开关用于清除所显示的内存数据。只有当原始故障得到纠正,并且在同一区域内没有其他故障时,才能清除该数据。
(e)LOC测试开关启动本地测试程序。
(f)DISP测试开关检查显示器。