机务在线

搜索
查看: 3013|回复: 5

[70-80发动机CFM56-7] Help....! 737 classics, LH Pack Ram Air Door not closing in cruise

[复制链接]

4

主题

142

帖子

219

积分

见习机务员

Rank: 2

积分
219
发表于 2010-2-20 09:03:31 | 显示全部楼层 |阅读模式 来自: 新西兰
Hi there,

This defect has an extensive histories. So far, the ram air temp sensor, ram air door actuator, turbo fan valve had been changed. Heat exchangers wash has also been done but the flight crew still keep reporting that the ram air door light won't go off in cruise but it went out when a/c descending to FL 300.

Any other suggestions about what else can be done??????
回复

使用道具 举报

4

主题

142

帖子

219

积分

见习机务员

Rank: 2

积分
219
 楼主| 发表于 2010-2-20 09:04:55 | 显示全部楼层 来自: 新西兰
Some more info about what have been done. The FIM task has been done for few times with no obvious fault found.
回复 支持 反对

使用道具 举报

37

主题

325

帖子

458

积分

元老

Rank: 13Rank: 13Rank: 13Rank: 13

积分
458
发表于 2010-2-20 11:33:52 | 显示全部楼层 来自: 中国广东深圳
这个故障经常发生:
原因比较多:作动器故障、灯显示故障、热交换器脏……
回复 支持 反对

使用道具 举报

1

主题

44

帖子

189

积分

见习机务员

Rank: 2

积分
189
发表于 2010-2-25 05:48:06 | 显示全部楼层 来自: 中国上海
classic不熟,制冷效果和右边的对比下,差很多的话会不会ACM问题?
回复 支持 反对

使用道具 举报

1

主题

44

帖子

189

积分

见习机务员

Rank: 2

积分
189
发表于 2010-2-26 17:07:49 | 显示全部楼层 来自: 中国上海
故障解决了吗?
回复 支持 反对

使用道具 举报

4

主题

142

帖子

219

积分

见习机务员

Rank: 2

积分
219
 楼主| 发表于 2010-2-27 10:51:00 | 显示全部楼层 来自: 新西兰
NO, stil happening intermittently.
回复 支持 反对

使用道具 举报

您需要登录后才可以回帖 登录 | 立即注册

本版积分规则

快速回复 返回顶部 返回列表