01
「更换氧气瓶时,要把氧气面罩要连接到手提氧气瓶的出口。」

你听有说过吗?

1504621730056.jpg

同事发来一个便携式氧气瓶更换的工卡:
(2).(b). 确认氧气面罩软管连接到调节器上的出口。
Make sure that the mask hose is connected to the outlet port on the regulator.

确实是有要求将氧气面罩软管连接到氧气瓶上。还有实际连接的照片:

1504621732565.jpg

然而,就我知道的情况,估计我们这里所有人都没有这么做。到底要不要机队下发一个普查单纠正过来呢?


02

赶紧先去翻了下手册:
AMM TASK 35-31-01-960-801
Replace Portable Oxygen Cylinder

1504621735161.jpg

R62版的AMM手册里果然是有这项要求,和工卡内容一致。看来我们之前换便携式氧气瓶都没有认真看手册啊。


1504621737945.jpg

然而到目前最新R63版的AMM:
(b) Connect the mask hose to the outlet port on the regulator if required by national authority.

这里加了一个条件:如果本国局方要求。

后来,询问了下公司的工程部门,得到的答复是:目前我们是不要求把氧气面罩连接到氧气瓶上的。

03
所以说,平时再干简单的工作,也要看手册,而且是看最新的手册。

AMM手册为什么突然就改版了呢?

感兴趣的可以看下这个FTD:
737NG-FTD-25-04007
Miscellaneous Cabin Safety Changes

1504621740370.jpg
1504621743208.jpg

Status
On 4 November 2004, Boeing released the referenced multi-operator message to advise operators of the new rules for production airplanes and for retrofit. One operator reported difficulty complying with the new rules for attaching masks to portable oxygen cylinders, as the assembly would no longer fit in the standard mounting locations. This operator posted the reference FLEET TEAM Bulletin Board item (02713) to solicit other operator comments on the new rules. Boeing has released Airplane Configuration Bulletin (ACB) B-S001-2005004540 to advise operators that they will need a master change for oxygen mask installation on production deliveries if the airplanes are to be operated under Part 121. The baseline configuration for current production airplanes will not be changed as the portable oxygen cylinder mask attachment and the other new rules are effected at FAR Part 25 amendment level 116, which is not applicable to current production airplanes. Closed issue.
Operator Action
US registered operators, or foreign operators who wish to comply with FAR 121, should contact your Customer Engineering Account Manager if interested in a Master Change for a proposal to reconfigure portable oxygen bottle installations on future deliveries. If interested in a proposal for retrofit of existing airplanes in your fleet, contact CAS Technical Services via email at airplaneservices@boeing.com or your CAS Sales Representative.

Please see the Referenced ACB B-S001-2005004540 for additional information.

也就是说,如果是在美国 FAA 121部下运营的飞机,需要将氧气面罩软管连接到氧气瓶上。


你之前有注意到吗?


欢迎关注微信公众号:阮工频道
回复

使用道具 举报

6

主题

67

帖子

481

积分

机务学徒工

Rank: 3Rank: 3

积分
481
发表于 2017-9-7 08:05:19 | 显示全部楼层 来自: 中国上海
厉害,工作够仔细
回复 支持 反对

使用道具 举报

0

主题

8

帖子

346

积分

机务学徒工

Rank: 3Rank: 3

积分
346
发表于 2017-10-23 21:20:03 | 显示全部楼层 来自: 中国四川成都
这图为何没有面罩包?直接绑上面的,晕