空速管,堵头之类的件号
** ON A/C ALL
TASK 10-11-00-555-013-A
Installation of the Aircraft Protection Equipment
WARNING: DO NOT APPLY ADHESIVE TAPE ON THE PROBES, DUCTS, SENSORS (STATIC, PITOT, TAT, AOA). USE ONLY THE SPECIFIED TOOLS FOR THE PROTECTION OF THE AIRCRAFT.THE SPECIFIED TOOLS:
- GIVE THE CORRECT PROTECTION TO THE AIRCRAFT EQUIPMENT,- ARE EASY TO SEE FROM THE GROUND,
- ARE EASY TO REMOVE.IF YOU USE TAPE, THERE IS A RISK THAT SOME TAPE, OR ADHESIVE FROM THE TAPE, WILL STAY ON THE PROBES, DUCTS OR SENSORS. THIS CAN CAUSE INCORRECT INDICATIONS ON THE RELATED COCKPIT INSTRUMENTS.
WARNING: YOU MUST BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE IS SHUTDOWN. THE ENGINE PARTS CAN STAY HOT FOR ALMOST 1 HOUR.
1. Reason for the Job
Self explanatory2. Job Set-up Information
A. Fixtures, Tools, Test and Support EquipmentREFERENCE QTY DESIGNATION
No specific 1 ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE No specific 1 WARNING NOTICE(S)(98A10001005000) 3 COVER-PITOT PROBE (98A10001013000) 2 COVER-TOTAL TEMP SENSOR (98A10001500000) 3 COVER-SLIP ON,ANGLE OF ATTACK SENSOR
** ON A/C 451-509, 511-650, 701-800(98D10003001000) 2 COVER-INLET COWL ENGINE
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950(98D10003002000) 2 COVER - INLET COWL ENGINE
** ON A/C ALL(98D10003003000) 3 COVER - SLIP-ON, AOA SENSOR (98D10007512000) 1 COVER-EXHAUST DUCT,APU (98D10007513000) 1 COVER-OILCOOLER OUTLET,APU (98D10103500001) 2 COVER-STATIC PROBE
** ON A/C 351-450, 701-750, 752-753, 801-900(98D10103501000) 2 COVER - ICE DETECTION PROBE
** ON A/C ALL(98F10001000000) 3 COVER AOA SENSOR
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950(HIX6002) 2 HALF PLUG, RIGHT-THRUST REVERSER (HIX6003) 2 HALF PLUG, LEFT-THRUST REVERSER
** ON A/C 451-509, 511-650, 701-800(IAE1N20008) 2 COVER-COMMON NOZZLE (IAE1N20400) 2 COVER-INLET COWL
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950(RSE1132) 2 COVER - COMMON NOZZLE (RSE1244) 2 COVER - INLET COWL ENGINE
** ON A/C ALL
B. Referenced Information
REFERENCE DESIGNATION** ON A/C 351-450, 701-750, 752-753, 801-900
Protective Equipment SHEET 1 ** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-350, 451-509, 511-700, 751-751, 754-800, 901-950
Protective Equipment SHEET 1 ** ON A/C 451-509, 511-650, 701-800
Protective Equipment SHEET 1 Protective Equipment SHEET 1 ** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950
Protective Equipment SHEET 1 Half Plug SHEET 1 ** ON A/C ALL
Protective Equipment SHEET 1 3. Job Set-up
Subtask 10-11-00-941-056-A A. Safety Precautions(1) On the panel 115VU:
- Make sure that the ENG/MODE selector switch is in the NORM position.- Make sure that the ENG/MASTER 1(2) control lever is in the OFF position.
(2) On the panel 25VU:- Make sure that the PROBE/WINDOW HEAT pushbutton switch is released (the ON legend is off).
(3) Put a WARNING NOTICE(S) in position in the cockpit to tell persons not to operate the systems while you install the protective devices on the aircraft. (4) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position near the aircraft.4. Procedure
** ON A/C 351-450, 701-750, 752-753, 801-900
EMB SB 34-1521 for A/C 405-405EMB SB 34-1564 for A/C 351-355, 405-405, 701-702
Subtask 10-11-00-555-069-A
A. Installation of the Protection Devices on the Fuselage(Ref. Fig. Protective Equipment SHEET 1)
WARNING: MAKE SURE THAT THE PROBES, THE ENGINE AND THE APU ARE COOL BEFORE INSTALLATION OF THE PROTECTIVE DEVICES. IF THE PROBES ARE HOT, THERE IS A RISK OF INJURY AND THE PROTECTIVE DEVICES CAN MELT.
(1) Protection of the 2 total temperature sensors
- Put the COVER-TOTAL TEMP SENSOR (98A10001013000) in position.(2) Protection of the 3 pitot probes
- Put the COVER-PITOT PROBE (98A10001005000) in position.(3) Protection of the 3 angle-of-attack sensors
- Put the COVER-SLIP ON,ANGLE OF ATTACK SENSOR (98A10001500000) or COVER - SLIP-ON, AOA SENSOR (98D10003003000) or COVER AOA SENSOR (98F10001000000) in position.(4) Protection of the 6 static probes
- Put the COVER-STATIC PROBE (98D10103500001) in position.(5) Protection of the 2 ice detection probes
- Put the COVER - ICE DETECTION PROBE (98D10103501000) in position.
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-350, 451-509, 511-700, 751-751, 754-800, 901-950EMB SB 34-1521 for A/C 056-056, 276-277, 279-280, 532-534
EMB SB 34-1564 for A/C 056-056, 276-277, 279-280, 451-452, 532-536, 551-552, 608-610
Subtask 10-11-00-555-069-BA. Installation of the Protection Devices on the Fuselage
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-350, 451-509, 511-700, 751-751, 754-800, 901-950
EMB SB 34-1521 for A/C 056-056, 276-277, 279-280, 532-534EMB SB 34-1564 for A/C 056-056, 276-277, 279-280, 451-452, 532-536, 551-552, 608-610
(Ref. Fig. Protective Equipment SHEET 1)
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-350, 451-509, 511-700, 751-751, 754-800, 901-950
EMB SB 34-1521 for A/C 056-056, 276-277, 279-280, 532-534EMB SB 34-1564 for A/C 056-056, 276-277, 279-280, 451-452, 532-536, 551-552, 608-610
WARNING: MAKE SURE THAT THE PROBES, THE ENGINE AND THE APU ARE COOL BEFORE INSTALLATION OF THE PROTECTIVE DEVICES. IF THE PROBES ARE HOT, THERE IS A RISK OF INJURY AND THE PROTECTIVE DEVICES CAN MELT.
(1) Protection of the 2 total temperature sensors
- Put the COVER-TOTAL TEMP SENSOR (98A10001013000) in position.(2) Protection of the 3 pitot probes
- Put the COVER-PITOT PROBE (98A10001005000) in position.(3) Protection of the 3 angle-of-attack sensors
- Put the COVER-SLIP ON,ANGLE OF ATTACK SENSOR (98A10001500000) or COVER - SLIP-ON, AOA SENSOR (98D10003003000) or COVER AOA SENSOR (98F10001000000) in position.(4) Protection of the 6 static probes
- Put the COVER-STATIC PROBE (98D10103500001) in position.
** ON A/C 451-509, 511-650, 701-800
Subtask 10-11-00-555-070-BB. Installation of the Protection Devices on the Engines
(Ref. Fig. Protective Equipment SHEET 1) (Ref. Fig. Protective Equipment SHEET 1)
WARNING: MAKE SURE THAT THE PROBES, THE ENGINE AND THE APU ARE COOL BEFORE INSTALLATION OF THE PROTECTIVE DEVICES. IF THE PROBES ARE HOT, THERE IS A RISK OF INJURY AND THE PROTECTIVE DEVICES CAN MELT.
(1) Protection of the engine air intakes- Put the COVER-INLET COWL (IAE1N20400) or COVER-INLET COWL ENGINE (98D10003001000) in position.
(2) Protection of the engine exhaust nozzles- Put the COVER-COMMON NOZZLE (IAE1N20008) in position.
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950
Subtask 10-11-00-555-070-D
B. Installation of the Protection Devices on the Engines
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950
(Ref. Fig. Protective Equipment SHEET 1) (Ref. Fig. Half Plug SHEET 1)
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950
WARNING: MAKE SURE THAT THE PROBES, THE ENGINE AND THE APU ARE COOL BEFORE INSTALLATION OF THE PROTECTIVE DEVICES. IF THE PROBES ARE HOT, THERE IS A RISK OF INJURY AND THE PROTECTIVE DEVICES CAN MELT.
(1) Protection of the engine air intakes
- Put the COVER - INLET COWL ENGINE (RSE1244) or COVER - INLET COWL ENGINE (98D10003002000) in position.(2) Protection of the engine exhaust nozzles
- Put the COVER - COMMON NOZZLE (RSE1132) in position.(3) Protection of the thrust reverser opening
- Put the HALF PLUG, RIGHT-THRUST REVERSER (HIX6002) and HALF PLUG, LEFT-THRUST REVERSER (HIX6003) in position.
** ON A/C ALL
Subtask 10-11-00-555-071-AC. Installation of the Protection Devices on the APU Area
(Ref. Fig. Protective Equipment SHEET 1)
WARNING: MAKE SURE THAT THE PROBES, THE ENGINE AND THE APU ARE COOL BEFORE INSTALLATION OF THE PROTECTIVE DEVICES. IF THE PROBES ARE HOT, THERE IS A RISK OF INJURY AND THE PROTECTIVE DEVICES CAN MELT.
(1) Protection of the APU exhaust duct- Put the COVER-EXHAUST DUCT,APU (98D10007512000) in position.
(2) Protection of the outlet duct of the APU oil cooler- Put the COVER-OILCOOLER OUTLET,APU (98D10007513000) in position.
5. Close-upSubtask 10-11-00-942-058-A A. Close-up
(1) Remove all the fixtures, tools, test and support equipment used during this procedure.
Figure 10-11-00-991-00100-02-A / SHEET 1 - Protective Equipment** ON A/C 351-450, 701-750, 752-753, 801-900 | EMB SB 34-1521 for A/C 405-405 | EMB SB 34-1564 for A/C 351-355, 405-405, 701-702
Figure 10-11-00-991-00100-02-B / SHEET 1 - Protective Equipment ** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-350, 451-509, 511-700, 751-751, 754-800, 901-950 | EMB SB 34-1521 for A/C 056-056, 276-277, 279-280, 532-534 | EMB SB 34-1564 for A/C 056-056, 276-277, 279-280, 451-452, 532-536, 551-552, 608-610
图片请见附件
Figure 10-11-00-991-00400-02-B / SHEET 1 - Protective Equipment** ON A/C 451-509, 511-650, 701-800
Figure 10-11-00-991-00700-02-A / SHEET 1 - Protective Equipment
** ON A/C 451-509, 511-650, 701-800
Figure 10-11-00-991-00400-02-C / SHEET 1 - Protective Equipment
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-950
Figure 10-11-00-991-00500-02-A / SHEET 1 - Half Plug
** ON A/C 001-049, 051-099, 101-149, 151-199, 201-220, 222-223, 225-227, 229-235, 239-249, 251-299, 301-450, 651-700, 801-95
Figure 10-11-00-991-00600-02-A / SHEET 1 - Protective Equipment |