使用拼接管修理导线时增加导线CAU值的方法:
1.png
回复

使用道具 举报

0

主题

12

帖子

1

积分

试用期机务

Rank: 1

积分
1
发表于 2024-9-19 16:59:04 | 显示全部楼层 来自: 中国上海
INCREASE OF CONDUCTOR CAU
A. Applicable Conditions
If the total CAU of the conductors is less than the minimum CAU of the conductor splice, increase the
CAU of the conductor.
For example, an AWG 20 wire can be assembled in a size 12-10 NAS1388 butt splice, but the CAU of
the AWG 20 conductor must be increased by a minimum of 31 CAU and a maximum of 126 CAU
because:
• The CAU of the AWG 20 conductor is 12
• The minimum CAU of the size 12-10 splice is 43
• The maximum CAU of the size 12-10 splice is 138.
Refer to:
• Paragraph 2.B. for the assembly of a conductor splice with a conductor that is folded back
• Paragraph 2.C. for the assembly of a conductor splice with a filler wire.
回复 支持 反对