驾驶舱和客舱温度控制工作测试(使用CFDS系统)
一、准备:
1.确认以下断路器闭合:
断路器板 名称 标识码 位置
49VU AIR COND/FLOW/CTL &/IND1 1HB D07
122VU AIR COND/FLOW/MIXER/FLAP 3HB V22
122VU AIR COND/FLOW/CTL AND IND/2 2HB V21
122VU AIR COND/ZONE TEMP CTL/28VDC/SYS2 4HK V20
122VU AIR COND/ZONE TEMP CTL/28VDC/SYS1 3HK V19
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS2 2HK V18
122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 1HK V17
122VU AIR COND/PACK TEMP/CTL SYS1/2/115VAC 21HH W22
122VU AIR COND/PACK TEMP/CTL SYS1/2/28VDC 23HH W21
122VU AIR COND/PACK TEMP/CTL SYS1/1/115VAC 1HH X22
122VU AIR COND/PACK TEMP/CTL SYS1/1/28VDC 3HH X21
122VU AIR COND/PACK TEMP CTL SYS2/2/28VDC 24HH Y21
122VU AIR COND/PACK TEMP CTL SYS2/2/115VAC 22HH Y20
122VU AIR COND/PACK TEMP CTL SYS2/1/28VDC 4HH Y19
122VU AIR COND/PACK TEMP CTL SYS2/1/115VAC 2HH Y18
122VU AIR COND/AFT CARGO VENT/FAN 30HN S22
122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/CTL 5HU U21
122VU AIR COND/LAV/GALLEY VENT CTL/EXTRACT FAN/SPLY 6HU U19
122VU AIR COND/AFT CARGO VENT/CTL AND/MONG 31HN S20
或备用位置
49VU AIR COND/AFT CARGO VENT/CTL&MONG 31HN C07
2.确认双发油门杆在慢车位。
3.确认30VU面板上,热空气按钮电门在接通位(OFF灯和FAULT灯熄灭),PACK1和PACK2按钮电门在关闭位(OFF灯亮)。
4.确认货舱加温面板22VU上,热空气按钮电门在接通位(OFF灯和FAULT灯熄灭)。
5.进入MCDU的SYSTEM REPORT/TEST AIR COND菜单。
二、测试程序:
警告:确认在冲压空气出口区域没有人员或设备,排出的热气能导致人员伤害或设备损坏。
工 作
| 结 果
| 1.在MCDU的空调菜单页上,按压TEM CTL行选键
| MCDU上出现CAB TEM CONT菜单页
| 2.在CAB TEM CONT菜单页,按压TEST行选键
| CAB TEM CONT TEST菜单页出现;
出现PACK1和PACK2 SELECT OFF信息
| 3.在CAB TEM CONT TEST菜单页,按压CONTINUE行选键
| 出现IN PROGRESS MAX 300S信息,然后出现TEST OK和END OF TEST信息。
|
参考:AMM 21-63-00 日期2005、10、26 |