4365| 12
|
[通用经验] 勤务工卡之发动机余油口渗漏 |
[/free]TASK 71-70-00-600-010
Leakage Rates at Drains Mast 1. Reason for the Job This task supplies the data to do a check of the leakage rates at the drains mast. 2. Job Set-up Information A. Fixtures, Tools, Test and Support Equipment REFERENCE QTY DESIGNATION No specific container 4l (1USgal) B. Referenced Information REFERENCE DESIGNATION 71-00-00-710-018 Discontinued Start, Restart and Shutdown Procedures 71-00-00-710-043 Normal Engine Automatic Start Procedure 71-00-00-710-047 Normal Engine Manual Start Procedure 71-00-00-860-012 Engine Safety Precautions 3. Job Set-up Subtask 71-70-00-869-050 A. Make sure that the engine safety precautions have been applied (Ref. AMM TASK 71-00-00-860-012) . Subtask 71-70-00-941-051 B. Put the container 4l (1USgal) below the drains mast. 4. Procedure Subtask 71-70-00-790-050 A. Start the engine (Ref. AMM TASK 71-00-00-710-043) or (Ref. AMM TASK 71-00-00-710-047) and set the engine power to idle. Subtask 71-70-00-790-051 B. Check for leaks at the drains mast CAUTION: IF DURING A COLD WEATHER START THE GROUND CREW REPORTS A FUEL LEAK FROM THE FUEL PUMP DRAIN MAST, RUN THE ENGINE AT IDLE FOR FIVE MINUTES. IF THE LEAK STOPS DURING THE FIVE MINUTES, THE AIRCRAFT CAN BE DISPATCHED WITHOUT MAINTENANCE ACTION. CAUTION: IF THE LEAK IS STILL PRESENT AFTER FIVE MINUTES, MAKE SURE THAT THE LEAKAGE RATE IS WITHIN THE LIMITS STATED IN TABLE 1. CAUTION: IF THE LEAKAGE RATE IS MORE THAN THE LIMITS STATED IN TABLE 1, THE AIRCRAFT CAN CONTINUE TO FLY FOR A MAXIMUM OF 25 HOURS OR 10 FLIGHTS, PROVIDED THAT THE LEAKAGE RATE IS NOT MORE THAN THE LIMITS STATED IN TABLE 2. (1) Compare the quantity got to the limits shown in the tables which follow: --------------------------------------------------------------------- Table 1 NOTE: The drops/minute rates are calculated from the formula that follows: 20 x cc/hr ----------------------- = Drops/Minute 60 --------------------------------------------------------------------- Table 2 5. Close-up Subtask 71-70-00-869-051 A. Stop the engine (Ref. AMM TASK 71-00-00-710-018) . Subtask 71-70-00-942-050 B. Remove the container and discard all drained fuel or oil. TASK 71-70-00-600-010 Leakage Rates at Drains Mast 1. Reason for the Job This task supplies the data to do a check of the leakage rates at the drains mast. 2. Job Set-up Information A. Fixtures, Tools, Test and Support Equipment REFERENCE QTY DESIGNATION No specific container 4l (1USgal) B. Referenced Information REFERENCE DESIGNATION 71-00-00-710-018 Discontinued Start, Restart and Shutdown Procedures 71-00-00-710-043 Normal Engine Automatic Start Procedure 71-00-00-710-047 Normal Engine Manual Start Procedure 71-00-00-860-012 Engine Safety Precautions 3. Job Set-up Subtask 71-70-00-869-050 A. Make sure that the engine safety precautions have been applied (Ref. AMM TASK 71-00-00-860-012) . Subtask 71-70-00-941-051 B. Put the container 4l (1USgal) below the drains mast. 4. Procedure Subtask 71-70-00-790-050 A. Start the engine (Ref. AMM TASK 71-00-00-710-043) or (Ref. AMM TASK 71-00-00-710-047) and set the engine power to idle. Subtask 71-70-00-790-051 B. Check for leaks at the drains mast CAUTION: IF DURING A COLD WEATHER START THE GROUND CREW REPORTS A FUEL LEAK FROM THE FUEL PUMP DRAIN MAST, RUN THE ENGINE AT IDLE FOR FIVE MINUTES. IF THE LEAK STOPS DURING THE FIVE MINUTES, THE AIRCRAFT CAN BE DISPATCHED WITHOUT MAINTENANCE ACTION. CAUTION: IF THE LEAK IS STILL PRESENT AFTER FIVE MINUTES, MAKE SURE THAT THE LEAKAGE RATE IS WITHIN THE LIMITS STATED IN TABLE 1. CAUTION: IF THE LEAKAGE RATE IS MORE THAN THE LIMITS STATED IN TABLE 1, THE AIRCRAFT CAN CONTINUE TO FLY FOR A MAXIMUM OF 25 HOURS OR 10 FLIGHTS, PROVIDED THAT THE LEAKAGE RATE IS NOT MORE THAN THE LIMITS STATED IN TABLE 2. (1) Compare the quantity got to the limits shown in the tables which follow: --------------------------------------------------------------------- Table 1 NOTE: The drops/minute rates are calculated from the formula that follows: 20 x cc/hr ----------------------- = Drops/Minute 60 --------------------------------------------------------------------- Table 2 5. Close-up Subtask 71-70-00-869-051 A. Stop the engine (Ref. AMM TASK 71-00-00-710-018) . Subtask 71-70-00-942-050 B. Remove the container and discard all drained fuel or oil. UNIT LIMIT DRAIN cc/hr drops/min MAST PORTS ------------------------------------------------------------------------------- FUEL UNITS Fuel Pumps - Fuel only 30 10 F.P Fuel Pumps - Fuel and Oil Mixture 30 10 F.P Fuel Pumps - Oil only 10 3 F.P Booster Stage Bleed Valve Actuator - Master 10 3 CORE Booster Stage Bleed Valve Actuator - Slave 10 3 CORE Fuel Diverter Unit 0 0 F.D Fuel Metering Unit 0 0 F.M.U Air Cooled Oil Cooler 0 0 A.C.O.C Active Clearance Control 10 3 CORE Variable Stator Vane Actuator 10 3 CORE OIL UNITS Air Starter 10 3 S Integrated Drive Generator 10 3 I.D.G HYDRAULIC UNIT Hydraulic Pump 10 3 HYD Table 1 UNIT LIMIT DRAIN cc/hr drops/min MAST PORTS ------------------------------------------------------------------------------- FUEL UNITS Fuel Pumps - Fuel only 120 40 F.P Fuel Pumps - Fuel and Oil Mixture 120 40 F.P Fuel Pumps - Oil only 10 3 F.P Booster Stage Bleed Valve Actuator - Master 120 40 CORE Booster Stage Bleed Valve Actuator - Slave 120 40 CORE Fuel Diverter Unit 120 40 F.D Fuel Metering Unit 120 40 F.M.U Air Cooled Oil Cooler 120 40 A.C.O.C Active Clearance Control 120 40 CORE Variable Stator Vane Actuator 120 40 CORE OIL UNITS Air Starter 10 3 S Integrated Drive Generator 10 3 I.D.G HYDRAULIC UNIT Hydraulic Pump 10 3 HYD Table 2 [free]
购买主题
本主题需向作者支付 5 JM机务米 才能浏览
| |
| ||
| ||
没人能阻止你上进~~~~~~~~~~~~~~
|
||
| ||
回 楼主(gdyong) 的帖子
| ||
| ||
| ||
| ||
自由飞翔
|
||
| ||
| ||
| ||
本网站属技术交流网站。
本论坛言论纯属发表者个人意见,与“机务在线”立场无关。
论坛严禁发布色情反动言论及有关违反国家法律法规内容!
情节严重者提供其IP,并配合相关部门进行严厉查处!
论坛资源由会员从网上收集整理或会员总结所得,版权属于原作者。
论坛所有资源是进行学习和经验交流之用,请在下载后24小时删除。
本站出于学习和维修目的进行交流和讨论,如有侵犯原作者的版权,
请告知我们,我们将立即做出整改,并给予相应的答复,谢谢合作!
我们的联系方式:电话:13686825091;微信:8268354
粤ICP备17048245号